“There Is No Substitute for Experience” DOW-KEY MICROWAVE 1U MS, MP, CB Matrix Series MS-1U18S-4/6-ENET CAN BUS RF SWITCH MATRIX Operator’s Manua

Seite 2

4 General Information 1.4 CB Matrices CB-Series stands for Crossbar. It is a matrix with several inputs connecting to several outputs. Only one input

Seite 3 - WARRANTY

5 General Information 1.5 Technical Specifications Refer to appendix A

Seite 4 - Manual Revision History

6 1.6 Safety Precaution Safety precautions should be observed before using this product and any associated instrumentation. This product is intende

Seite 5 - Table of Contents

7 2 System Layout 2.1 Front Panel Layout Figure 2-1 shows the 1U Model general layout, which includes: • 2 handles • Three LED, LCD and keypad

Seite 6

8 System Layout 2.2 Rear Panel Layout Figure 2-2 shows an example of a 1U model rear panel general layout. All models have common parts which includ

Seite 7 - 1 General Information

9 System Layout System Layout 2.3 Top View Layout Figure 2-3 shows the top view layout of all models. Figure 2-3, Top View of 1U Models

Seite 8 - 1.2 MS Matrices

10 System Layout 2.4 RF configuration Refer to appendix B.

Seite 9 - 1.3 MP Matrices

11 3 Connections 3.1 Power Connection 3.1.1 Line Voltage The matrix operates from a line voltage in the range of 110V to 240V at a frequency of 50 o

Seite 10 - 1.4 CB Matrices

12 Connections Insert small bladed screwdriver to release the fuse. Figure 3-1, Power Entry Module Line Voltage Fuse Rating Manufacturer Manufactu

Seite 11 - 1.5 Technical Specifications

13 Connections Pin 1 NC Pin 2 Transmit Pin 3 Receive Pin 4 NC Pin 5 Ground Pin 6 NC Pin 7 NC Pin 8 NC Pin 9 NC Table 3-2, RS232 Female Conne

Seite 12 - 1.9 Repacking for shipment

Copyright © Dow-Key Microwave Corporation 2012, all rights reserved. Information in this publication supersedes that in all previously published mate

Seite 13 - 2 System Layout

14 Connections 3.5 Ethernet Connection The matrix comes equipped with an Ethernet port (RJ45 connector) which allows the user to easily access the ma

Seite 14 - 2.2 Rear Panel Layout

15 4 Configuring the Matrix for Operation 4.1 Matrix Configuration The ‘brain’ inside Dow-Key Matrices, referred to as the “Matrix Controller”, has b

Seite 15 - 2.3 Top View Layout

16 Configuring the Matrix 4.3 Adding and Deleting Switches The following rules apply when adding a switch to the Matrix Configuration (the desired I

Seite 16 - 2.4 RF configuration

17 Configuring the Matrix Example procedure: Adding a switch to the Configuration usually starts by finding the ID of the physical switch to add. Se

Seite 17 - 3 Connections

18 Configuring the Matrix 4.5 Connection to an Ethernet The use of a standard “Straight Through” Ethernet cable is required to connect the matrices

Seite 18 - 3.3 RS232 Connection

19 Configuring the Matrix 4.5 Testing Ethernet Communication The matrix’s ability to communicate should be tested once it has been configured and co

Seite 19 - 3.4 CAN Bus Connection

20 Configuring the Matrix In both the above scenarios a valid and working connection will yield a response similar that shown in the example below:

Seite 20 - 3.6 USB Port

21 5 Manual (LOCAL) Operation 5.1 The Keypad / LCD Interface Power On: Position the rocker switch on the rear panel of the Matrix to the on positi

Seite 21 - 4.1 Matrix Configuration

22 Manual (LOCAL) Operation UP and DOWN serve as “scroll up”, “scroll down”, “increment”, or “decrement”. Many data fields’ values are modified by

Seite 22

23 Manual (LOCAL) Operation 5.2 Main Menu 5.2.1 Switching Operations Switch Operations Menu Set Switch Positions View the currently set position a

Seite 23

iii WARRANTY Dow-Key Microwave Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from date

Seite 24

24 Manual (LOCAL) Operation Recall Positions Recall from non-volatile memory the state of the positions of all switch ID’s configured to the matrix,

Seite 25

25 Manual (LOCAL) Operation 5.2.2 Error Operations View the contents of the Error Log (see Section 6.5.1). Each entry is displayed with the oldest b

Seite 26

26 Manual (LOCAL) Operation 5.2.3 System Settings System Settings Menu ! Important Note: The matrix controller is designed to offer the maximum expa

Seite 27 - 5 Manual (LOCAL) Operation

27 Manual (LOCAL) Operation 4. NOTE: this operation “puts the matrix’s switches to sleep” thereby rendering the matrix inoperable during the proces

Seite 28

28 Manual (LOCAL) Operation 5.2.4 Ethernet Options Actual changes to the Ethernet variables referred to below will not take effect nor be shown on t

Seite 29 - 5.2 Main Menu

29 Manual (LOCAL) Operation 5.2.5 LCD Options View and adjust the brightness and contrast of the LCD. Changes made here are persistent over power d

Seite 30

30 6 Remote Operation 6.1 Introduction to SCPI SCPI is a command structure that is based on the IEEE-488.2 specification which Dow-key has adapte

Seite 31

31 Remote Operation 6.3 Command Separators and conventions • A colon (:) is used to separate a command keyword from a lower level keyword. • A bla

Seite 32

32 Remote Operation 6.4 Common Commands The following contains the common commands of SCPI that the Ethernet controller is compatible with. The poss

Seite 33

33 Remote Operation 6.4.2 *OPC? Syntax *OPC? Description This query returns an ASCII character “1” when all pending operations have been finished.

Seite 34

iv Manual Revision History The revision history shown below lists all revisions and addendums created for this manual. The revision level increases n

Seite 35

34 Remote Operation 6.4.3 *RST Syntax *RST Description This command performs a device reset. This will set the instrument so that all switches are

Seite 36 - 6 Remote Operation

35 Remote Operation Example “SYST:ERR?” Result was “1, INVALID CHARACTER”, check for more errors. Description: This error is no longer supporte

Seite 37

36 Remote Operation SYST:ERR?” Result was “10, SWITCH DID NOT RESPOND”, check for more errors. Description: One of the switches did not respond to a

Seite 38

37 Remote Operation SYST:ERR?” Result was “30, COMMAND UNRECOGNIZED”, check for more errors. Description: This error code is generated when the comm

Seite 39

38 Remote Operation 6.5.2 SYST:IPADDRESS? Syntax SYSTem:IPADDRESS? Description Returns the matrix IP address. Result xxx.yyy.zzz.aaa Possible err

Seite 40

39 Remote Operation 6.5.4 SYST:TCPPORT? Syntax SYSTem:TCPPORT? Description Returns the matrix TCP Port number. Result n Possible error codes No

Seite 41

40 Remote Operation 6.5.6 SYST:GATEWAY? Syntax SYSTem:GATEWAY? Description Returns the matrix gateway address. Result xxx.yyy.zzz.aaa Possible er

Seite 42

41 Remote Operation 6.5.7 SYST:GATEWAY xxx.yyy.zzz.aaa Syntax SYSTem:GATEWAY xxx.yyy.zzz.aaa Description Sets matrix gateway address to xxx.yyy.zzz

Seite 43

42 Remote Operation 6.5.9 SYST:MASK xxx.yyy.zzz.aaa Syntax SYSTem:MASK xxx.yyy.zzz.aaa Description Sets the matrix subnet mask address to xxx.yyy.z

Seite 44

43 Remote Operation 6.5.11 SYST:SERIALNUMBER? Syntax SYSTem:SERIALNUMBER? Description Returns the matrix serial number. Result n Possible error c

Seite 45

v Table of Contents 1 General Information ... 11.

Seite 46

44 Remote Operation 6.5.13 SYST:TIMEOUT x Syntax SYSTem:TIMEOUT x Description The Timeout is used to automatically close the TCP/IP socket after a

Seite 47

45 Remote Operation 6.5.14 SYST:STATUS? Syntax SYSTem:STATUS? Description This command will return all Switch positions, Local/Remote mode, Power s

Seite 48

46 Remote Operation 6.5.15 SYST:SCREENSAVER? Syntax SYSTem:SCREENSAVER? Description This command will return the screen saver time settings n (n is

Seite 49

47 Remote Operation 6.6 Switch [Module] Command Set The following contains the switch [module] commands of SCPI that the Ethernet control is compat

Seite 50

48 Remote Operation 6.6.2 Setting switch x to position n x = switch [module] address. n = position to set and must be within the switches parameter

Seite 51

49 Remote Operation 6.6.3 Requesting Switch x current position x = switch address. Examples: • ROUTE:SWITCHx? • ROUT:SWITx? • :SWITx? Result: Retu

Seite 52

50 Remote Operation 6.7 DHCP Command Set The following contains the DHCP (Dynamic Host Configuration Protocol) commands of SCPI that the Ethernet c

Seite 53

51 Remote Operation This page intentionally left blank

Seite 54

52 RS232, USB and Ethernet Command description for standard matrices Command Syntax Response Action 1 *IDN? MS-1U18S-4/6-ENET Returns string in ’

Seite 55

53 Remote Operation Note: 1. Commands are NOT case sensitive. 2. Every command and response on the Ethernet and serial port should have “\r\n” Car

Seite 56

vi 6.4.3 *RST ... 346.5 System Commands ...

Seite 57 - Remote Operation

54 7 Web Page Server (HTTP) 7.1 Web Page Server Control The matrix may be controlled by way of web pages served by the matrix over its Ethernet port

Seite 58

55 Web Page Server 7.2 Matrix Control Clicking on ‘Matrix control’ will show the below page. Remote mode commands may be typed into the Command tex

Seite 59

56 Web Page Server 7.3 Matrix Configuration Clicking on ‘Matrix configuration’ will show the below page. ! Important Note: The matrix controller i

Seite 60 - 7 Web Page Server (HTTP)

57 Web Page Server 7.4 Matrix Status Clicking on ‘Matrix status’ will show the below page. This page displays the current status of alarm sources

Seite 61 - 7.2 Matrix Control

58 Appendix A Technical Specifications Model: MS-1U18S-4/6-ENET Configuration: Four SP6T switches mounted on the rear panel RF Connectors:

Seite 62 - 7.3 Matrix Configuration

59 Appendix B RF Configuration Model: MS-1U18S-4/6-ENET Four normally open SP6T switches (Dow-Key part number: 565-5208-3-ROHS) mounted on the rear

Seite 63 - 7.4 Matrix Status

1 1 General Information 1.1 Introduction The Dow-Key Microwave 1U MS, MP, CB Switch Matrix series are electromechanical RF matrices. They come equip

Seite 64 - Appendix A

2 General Information 1.2 MS Matrices MS-Series stands for Multiple Switches. It is a matrix where a number of independent switches are populated on

Seite 65 - Appendix B

3 General Information 1.3 MP Matrices MP-Series stands for Multiplexer. It is a matrix with one input connecting to many outputs (only one at the tim